08 0326_08 0325_25092017_230352.mpg
3.9 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start
3.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start
45.8 ft. - Broken, at 12 o'clock, within 8 inches of joint: YES
46.6 ft. - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 4", 2" - CAPPED BROKEN
54 ft. - Crack Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
236.3 ft. - Crack Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish
236.3 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
331.3 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish
| Distance | Code | Observation |
|---|---|---|
| 236.3 | CH2 | — |
| 337.2 | MGO | SERVICE CONNECTION AT 9 O'CLOCK AT MH |
| 54 | CL | — |
| 0 | MWL | — |
| 45.8 | B | — |
| 3.9 | CL | — |
| 46.6 | TFC | — |
| 0.1 | MWM | — |
| 46.6 | TFD | CAPPED BROKEN |
| 0 | AMH | 08 0326 |
| 54 | CH2 | — |
| 101 | TFC | — |
| 152 | TFC | — |
| 251 | TFC | — |
| 337.2 | AMH | 08 0325 |
| 298.7 | TF | — |
| 54 | CL | — |
| 331.3 | FH2 | — |
| 236.3 | FH2 | — |
| 200.1 | TFC | — |
| 3.9 | CL | — |