Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 4, 2018, 07:54 AM
  • 02 1793_02 1637_04102018_010327.mp4

Date
10/04/2018
W/O
729701
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00292
PipeID
P04138
Time
12:54 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6129
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_729701_TV02108_OCT2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1793
Downstream MH
02 1637
Dir. of Survey
Downstream
Length Surveyed
162.8 ft.
Total Length
162.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 1793 to 02 1637
MH: 02 1793MH: 02 1637downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 17930 ft. MWL - Water Level, 5 %of cross sectional area2.9 ft. MGO - General Observation - LINED PIPE24.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"65.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"90.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"117.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"162.8 ft. AMH - Downstream Manhole, Survey Ends - 02 1637162.8 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK162.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (11)

DistanceCodeObservation
162.8AMH02 1637
162.8MGOCONNECTION AT MH 12 O'CLOCK
162.8MGOCONNECTION AT MH 3 O'CLOCK
24.6TF
0MWM
65.9TF
0AMH02 1793
117.6TF
90.3TF
2.9MGOLINED PIPE
0MWL

Properties (4)

additional_info
SC364848
custom_field_two
3
customer
LACSD
datetime
2018-10-04T00:54:19-07:00