- Date
- 11/30/2017
- W/O
- 674573
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00254
- PipeID
- P04106
- Time
- 12:31 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5055
- Sewer Name
- 02 DOWNEY-BELLFLOWER EXTENSION TRUNK
- City
- PICO RIVERA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- WO_674573_TV02052_DEC2017
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 02 1759A
- Downstream MH
- 02 1759
- Dir. of Survey
- Downstream
- Length Surveyed
- 201.9 ft.
- Total Length
- 201.9 ft.
- Structural Index
- 3
- Structural Quick
- 3E13
- Structural Rating
- 93
- O&M Index
- 1
- O&M Quick
- 1100
- O&M Rating
- 1
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 94
Pipe schematic from manhole 02 1759A to 02 1759 Observation photos (5)

6.1 ft. - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

17.8 ft. - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

39.1 ft. - Crack Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

49.8 ft. - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

57 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start