Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2017, 07:32 AM
  • 02 1761_02 1760 _29112017_233252.mp4

Date
11/29/2017
W/O
674573
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00254
PipeID
P04108
Time
11:32 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5055
Sewer Name
02 DOWNEY-BELLFLOWER EXTENSION TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
15
Purpose
Routine Assessment
Project
WO_674573_TV02052_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1761
Downstream MH
02 1760
Dir. of Survey
Downstream
Length Surveyed
262.5 ft.
Total Length
262.5 ft.
Structural Index
3
Structural Quick
413I
Structural Rating
160
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
160
Pipe schematic from manhole 02 1761 to 02 1760
MH: 02 1761MH: 02 1760downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 17613.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start38 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"114.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"164.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"172.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"249.6 ft. FM - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES262.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK262.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK262.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish262.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1760

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    249.6 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
0MWL
262.5MGOCONNECTION AT MH 9 O'CLOCK
38TF
262.5MGOCONNECTION AT MH 3 O'CLOCK
164.1TF
249.6FM
114.3TF
172.2TF
3.4CM
0MWM
262.5CM
0AMH02 1761
262.5AMH02 1760

Properties (4)

additional_info
SC346284
custom_field_two
3
customer
LACSD
datetime
2017-11-29T23:32:26-08:00