Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 16, 2016, 09:48 AM
  • 02 1590_02 1589_20160816_040414.mpg

Date
08/16/2016
W/O
585987
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00231
PipeID
P04044
Time
2:48 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3420
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 2
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_585987_TV02010_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1590
Downstream MH
02 1589
Dir. of Survey
Downstream
Length Surveyed
287.4 ft.
Total Length
287.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2J12
O&M Rating
116
Overall Index
2
Overall Quick
Overall Rating
116
Pipe schematic from manhole 02 1590 to 02 1589
MH: 02 1590MH: 02 1589downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 15900 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start8.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"56.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"104.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"118.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 4"133.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"181.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"229.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"281 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"284.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish287.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1589287.4 ft. VC - Vermin Cockroach

Observation photos (9)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    8.8 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    56.4 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    104.1 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    118.7 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    133.4 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    181.6 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    229.9 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    281 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"

Observations (16)

DistanceCodeObservation
287.4AMH02 1589
56.4TF
287.4VC
281TF
229.9TF
133.4TF
0MWM
181.6TF
8.8TF
0AMH02 1590
104.1TF
118.7TB
2DAGS
284.9DAGS
0VC
0MWL

Properties (4)

additional_info
SC305973
custom_field_two
4
customer
LACSD
datetime