Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 18, 2016, 08:47 AM
  • H 1420_H 1419 _18082016_014816.mp4

Date
08/18/2016
W/O
585476
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01204
PipeID
P16291
Time
1:47 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3568
Sewer Name
H JOINT OUTFALL H - UNIT 8M
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
30
Purpose
Routine Assessment
Project
WO_585476_TV22034_AUG2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
H 1420
Downstream MH
H 1419
Dir. of Survey
Downstream
Length Surveyed
184.8 ft.
Total Length
184.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole H 1420 to H 1419
MH: H 1420MH: H 1419downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 14200 ft. MGO - General Observation - LATERAL AT MH CAPPED 3 OCLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area2.4 ft. MGO - General Observation - MAG COAT 80%11.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"34.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"184.8 ft. AMH - Downstream Manhole, Survey Ends - H 1419

Observations (9)

DistanceCodeObservation
184.8AMHH 1419
0MWL
34.7TFC
2.4MGOMAG COAT 80%
0AMHH 1420
11.8TF
0MGOLATERAL AT MH CAPPED 3 OCLOCK
128.2TFA
0MWM

Properties (4)

additional_info
SC306151
custom_field_two
4
customer
LACSD
datetime
2016-08-18T01:47:43-07:00