Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 16, 2016, 07:13 AM
  • 05 1650_05 1649 _061616_001350.mpg

Date
06/16/2016
W/O
563399
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06873
Time
12:13 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3398
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
30
Purpose
Routine Assessment
Project
WO_563399_TV05132_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1650
Downstream MH
05 1649
Dir. of Survey
Downstream
Length Surveyed
395.6 ft.
Total Length
395.6 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
237
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
237
Pipe schematic from manhole 05 1650 to 05 1649
MH: 05 1650MH: 05 1649downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 16500 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK3 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES6.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start62.2 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"72.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"112.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"158 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"169.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"191.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"231.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"270.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"310.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"322.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"349.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"384.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"395.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish395.6 ft. AMH - Downstream Manhole, Survey Ends - 05 1649

Observation photos (5)

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    3 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    6.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    62.2 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    169.3 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    322.7 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (20)

DistanceCodeObservation
169.3TB
384.7TFA
270.9TF
6.4CM
72.3TFA
62.2TB
0MWM
3CM
112.7TFA
349.4TFC
395.6CM
158TF
395.6AMH05 1649
0AMH05 1650
310.3TF
0MWL
231.5TF
191.7TF
0MGOCONNECTION AT THE MH 9 O'CLOCK
322.7TB

Properties (4)

additional_info
SC300398
custom_field_two
3
customer
LACSD
datetime
2016-06-16T00:13:20-07:00