Section#2_F 0031_F 0030__852017__G6792.mp4
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2.2 ft. - General Observation - MAG COAT 85% START 9:00 TO 3:00
2.2 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
34.8 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT
61.1 ft. - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM REBAR BROKEN
131.7 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
134.3 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
185.1 ft. - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN
303.3 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 342 | SAM | SEVERE AGG |
| 2.2 | MGO | MAG COAT 85% START 9:00 TO 3:00 |
| 0 | MWM | — |
| 0 | AMH | 2:45AM |
| 175.7 | TF | ACTIVE |
| 342 | SRV | CIRCUM REBAR |
| 214.9 | TF | ACTIVE |
| 2 | SAM | SEVERE AGG |
| 303.3 | SRV | CIRCUM REBAR |
| 134.3 | SAM | SEVERE AGG |
| 34.8 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 131.7 | SRV | CIRCUM REBAR |
| 61.1 | SRC | CIRCUM REBAR BROKEN |
| 342.5 | AMH | 3:15AM |
| 2.2 | SRV | CIRCUM REBAR |
| 185.1 | SRC | CIRCUM REBAR BROKEN |
| 0 | MWL | — |