Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 5, 2017, 09:01 AM
  • Section#2_F 0031_F 0030__852017__G6792.mp4

Date
08/05/2017
W/O
0646716
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00033
PipeID
P10121
Time
2:01 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6792
Sewer Name
F JOINT OUTFALL F - UNIT 1
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20170805MDM_JOINT_OUTFALL_F_UNIT_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
69 in.
Upstream MH
F 0031
Downstream MH
F 0030
Dir. of Survey
Downstream
Length Surveyed
342.5 ft.
Total Length
342.5 ft.
Structural Index
5
Structural Quick
5N4M
Structural Rating
641
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
645
Pipe schematic from manhole F 0031 to F 0030
MH: F 0031MH: F 0030downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:45AM0 ft. MWL - Water Level, 40 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2.2 ft. MGO - General Observation - MAG COAT 85% START 9:00 TO 3:002.2 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR34.8 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT61.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM REBAR BROKEN131.7 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR134.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG175.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE185.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN214.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE303.3 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR342 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG342 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR342.5 ft. AMH - Downstream Manhole, Survey Ends - 3:15AM

Observation photos (9)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 85% START 9:00 TO 3:00

    2.2 ft. - General Observation - MAG COAT 85% START 9:00 TO 3:00

  • Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    2.2 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT

    34.8 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT

  • Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM REBAR BROKEN

    61.1 ft. - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM REBAR BROKEN

  • Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    131.7 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    134.3 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN

    185.1 ft. - Surface Reinforcement Corroded, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN

  • Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    303.3 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

Observations (17)

DistanceCodeObservation
342SAMSEVERE AGG
2.2MGOMAG COAT 85% START 9:00 TO 3:00
0MWM
0AMH2:45AM
175.7TFACTIVE
342SRVCIRCUM REBAR
214.9TFACTIVE
2SAMSEVERE AGG
303.3SRVCIRCUM REBAR
134.3SAMSEVERE AGG
34.8SRVCIRCUM REBAR UNDER MAG COAT
131.7SRVCIRCUM REBAR
61.1SRCCIRCUM REBAR BROKEN
342.5AMH3:15AM
2.2SRVCIRCUM REBAR
185.1SRCCIRCUM REBAR BROKEN
0MWL

Properties (4)

custom_field_three
CIRCUM REBAR CORRODED
custom_field_two
2
customer
LACSD
datetime
2017-08-05T02:01:01-07:00