Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 5, 2017, 07:58 PM
Date
10/05/2017
W/O
663250
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00025
PipeID
P00530
Time
12:58 PM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4290
Sewer Name
08 216TH STREET RELOCATION TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_663250_TV08101_OCT2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
08 0596
Downstream MH
D 0008
Dir. of Survey
Downstream
Length Surveyed
713.1 ft.
Total Length
713.1 ft.
Structural Index
4
Structural Quick
5231
Structural Rating
13
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
13
Pipe schematic from manhole 08 0596 to D 0008
MH: 08 0596MH: D 0008downstream0 ft. MWL - Water Level, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins0.1 ft. MWM - Water Mark, 45 %of cross sectional area25.1 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start25.1 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start494.3 ft. SRC - Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES708.6 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish708.6 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish711.7 ft. MWM - Water Mark, 35 %of cross sectional area711.7 ft. MWL - Water Level, 35 %of cross sectional area713.1 ft. AMH - Downstream Manhole, Survey Ends

Observation photos (3)

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    25.1 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    25.1 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES

    494.3 ft. - Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
711.7MWM
25.1SRV
0.1MWM
0MWL
713.1AMH
711.7MWL
494.3SRC
0AMH
25.1SAP
708.6SAP
708.6SRV

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2017-10-05T12:58:51-07:00