17 0037_17 0036_19022016_000821.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
6.3 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES
135.6 ft. - Roots Medium Connection, from 12 to 03 o'clock, 5 %, within 8 inches of joint: YES
135.6 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS
190.9 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS
190.9 ft. - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES
204.5 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS
258.2 ft. - Roots Fine Connection, from 12 to 03 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 135.6 | RMC | — |
| 276 | DAGS | — |
| 0 | MWM | — |
| 0 | MGO | ACTIVE CONNECTION AT MH 9 O'CLOCK |
| 0 | AMH | 17 0037 |
| 135.6 | TFD | ROOTS |
| 0 | MWL | — |
| 2 | DAGS | — |
| 6.3 | CM | — |
| 190.9 | TFD | ROOTS |
| 190.9 | RFC | — |
| 204.5 | TFD | ROOTS |
| 258.2 | RFC | — |
| 277.5 | AMH | 17 0036 |
| 212.6 | TFA | — |
| 258.2 | TFA | — |
| 99.5 | TFC | — |