Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 19, 2016, 08:07 AM
  • 17 0037_17 0036_19022016_000821.mp4

Date
02/19/2016
W/O
552350
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00668
PipeID
P13760
Time
12:07 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3261
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
06
Purpose
Routine Assessment
Project
WO_552350_TV17001_FEB2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Other
Height
24 in.
Upstream MH
17 0037
Downstream MH
17 0036
Dir. of Survey
Downstream
Length Surveyed
277.5 ft.
Total Length
277.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
3125
O&M Rating
15
Overall Index
2
Overall Quick
Overall Rating
18
Pipe schematic from manhole 17 0037 to 17 0036
MH: 17 0037MH: 17 0036downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 17 00370 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.3 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES99.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"135.6 ft. RMC - Roots Medium Connection, from 12 to 03 o'clock, 5 %, within 8 inches of joint: YES135.6 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS190.9 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS190.9 ft. RFC - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES204.5 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS212.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"258.2 ft. RFC - Roots Fine Connection, from 12 to 03 o'clock, within 8 inches of joint: YES258.2 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"276 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish277.5 ft. AMH - Downstream Manhole, Survey Ends - 17 0036

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    6.3 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Roots Medium Connection, from 12 to 03 o'clock, 5 %, within 8 inches of joint: YES

    135.6 ft. - Roots Medium Connection, from 12 to 03 o'clock, 5 %, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    135.6 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    190.9 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES

    190.9 ft. - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    204.5 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Fine Connection, from 12 to 03 o'clock, within 8 inches of joint: YES

    258.2 ft. - Roots Fine Connection, from 12 to 03 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
135.6RMC
276DAGS
0MWM
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0AMH17 0037
135.6TFDROOTS
0MWL
2DAGS
6.3CM
190.9TFDROOTS
190.9RFC
204.5TFDROOTS
258.2RFC
277.5AMH17 0036
212.6TFA
258.2TFA
99.5TFC

Properties (4)

additional_info
SC225483
custom_field_two
4
customer
LACSD
datetime
2016-02-19T00:07:39-08:00