Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 1, 2017, 07:37 AM
  • 01 1086_01 1085_28022017_233756.mp4

Date
02/28/2017
W/O
619125
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00210
PipeID
P01935
Time
11:37 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
4362
Sewer Name
01 HUNTINGTON PARK TRUNK
City
CUDAHY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
WO_619125_TV01246_FEB2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
01 1085
Downstream MH
01 1086
Dir. of Survey
Upstream
Length Surveyed
219.9 ft.
Total Length
219.9 ft.
Structural Index
2
Structural Quick
2C00
Structural Rating
44
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
44
Pipe schematic from manhole 01 1085 to 01 1086
MH: 01 1085MH: 01 1086upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 10860 ft. MGO - General Observation - CONNECTION AT MH 11 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish99.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start120.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES170.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES219.9 ft. MWM - Water Mark, 25 %of cross sectional area219.9 ft. AMH - Downstream Manhole, Survey Begins - 01 1085219.9 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (3)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    49.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    99.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    120.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWM
219.8CL
219.9AMH01 1086
49.8CL
0AMH01 1085
120.6CL
219.9MGOCONNECTION AT MH 11 O'CLOCK
0MWL
219.9MGOCONNECTION AT MH 9 O'CLOCK
99.1CL

Properties (4)

additional_info
SC306874
custom_field_two
3
customer
LACSD
datetime