Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2016, 05:01 AM
  • 02 1375_02 1374 _12102016_222521.mp4

Date
10/12/2016
W/O
597385
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00245
PipeID
P03895
Time
10:01 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3428
Sewer Name
02 DITMAN STREET BRANCH TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_597385_TV02045_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1375
Downstream MH
02 1374
Dir. of Survey
Downstream
Length Surveyed
317.6 ft.
Total Length
317.6 ft.
Structural Index
3
Structural Quick
3400
Structural Rating
12
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 02 1375 to 02 1374
MH: 02 1375MH: 02 1374downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13750 ft. VC - Vermin Cockroach0 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0.1 ft. MWM - Water Mark, 35 %of cross sectional area30.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"67.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"76.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"159.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"208.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"256.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"256.6 ft. LFCS - Lining Failure Connection Cut Shifted, from 08 to 11 o'clock, within 8 inches of joint: NO264.3 ft. LFCS - Lining Failure Connection Cut Shifted, from 01 to 05 o'clock, within 8 inches of joint: YES264.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"300.2 ft. LFCS - Lining Failure Connection Cut Shifted, from 08 to 11 o'clock, within 8 inches of joint: YES300.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"309.9 ft. LFCS - Lining Failure Connection Cut Shifted, at 02 o'clock, within 8 inches of joint: NO317.6 ft. AMH - Downstream Manhole, Survey Ends - 02 1374

Observation photos (4)

  • Lining Failure Connection Cut Shifted, from 08 to 11 o'clock, within 8 inches of joint: NO

    256.6 ft. - Lining Failure Connection Cut Shifted, from 08 to 11 o'clock, within 8 inches of joint: NO

  • Lining Failure Connection Cut Shifted, from 01 to 05 o'clock, within 8 inches of joint: YES

    264.3 ft. - Lining Failure Connection Cut Shifted, from 01 to 05 o'clock, within 8 inches of joint: YES

  • Lining Failure Connection Cut Shifted, from 08 to 11 o'clock, within 8 inches of joint: YES

    300.2 ft. - Lining Failure Connection Cut Shifted, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Lining Failure Connection Cut Shifted, at 02 o'clock, within 8 inches of joint: NO

    309.9 ft. - Lining Failure Connection Cut Shifted, at 02 o'clock, within 8 inches of joint: NO

Observations (18)

DistanceCodeObservation
30.1TF
256.6TFA
67.3TFA
76.2TFA
0AMH02 1375
300.2LFCS
264.3LFCS
208.1TF
159.1TFA
300.2TFA
0VC
256.6LFCS
264.3TF
0.1MWM
309.9LFCS
0MGOCONNECTION AT MH 9 ACTIVE
0MWL
317.6AMH02 1374

Properties (6)

additional_info
SC303462
custom_field_two
4
customer
LACSD
datetime
2016-10-12T22:01:18-07:00
lining
PVCP-Folded/Reformed
year_laid
38394