- Date
- 10/25/2018
- W/O
- 0736430
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00091
- PipeID
- P08909
- Time
- 4:08 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1028
- Sewer Name
- B JOINT OUTFALL B - UNIT 5A
- City
- SAN MARINO
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- 20181025MDM_JOINT_OUTFALL_B_UNIT_5A
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- B 0397
- Downstream MH
- B 0396
- Dir. of Survey
- Downstream
- Length Surveyed
- 275.5 ft.
- Total Length
- 275.5 ft.
- Structural Index
- 2
- Structural Quick
- 2200
- Structural Rating
- 4
- O&M Index
- 4
- O&M Quick
- 4200
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole B 0397 to B 0396 Observation photos (5)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTEING CONCRETE

8 ft. - General Observation - 24" RCP

21.7 ft. - General Observation - 50% MAG COAT START

169.8 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

193.9 ft. - Water Mark, 70 %of cross sectional area