Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 12, 2018, 07:25 AM
  • 17 0020_17 0019 _12092018_002608.mp4

Date
09/12/2018
W/O
724194
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00668
PipeID
P13744
Time
12:25 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6001
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
06
Purpose
Routine Assessment
Project
WO_724194_TV17004_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
17 0020
Downstream MH
17 0019
Dir. of Survey
Downstream
Length Surveyed
165.6 ft.
Total Length
165.6 ft.
Structural Index
4
Structural Quick
4D39
Structural Rating
119
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
119
Pipe schematic from manhole 17 0020 to 17 0019
MH: 17 0020MH: 17 0019downstream0 ft. AMH - Upstream Manhole, Survey Begins - 17 00200 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 30 %of cross sectional area4.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start49.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish49.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start65.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"113.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"117.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"133.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"136.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"165.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    49.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    65.6 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    113.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    133.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    136.9 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (13)

DistanceCodeObservation
117.9TB
136.9TB
4.6CM
49.5CM
0AMH17 0020
133.8TB
165.6FM
113.4TB
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
49.5FM
65.6TB
0MWL

Properties (4)

additional_info
SC364816
custom_field_two
2
customer
LACSD
datetime
2018-09-12T00:25:38-07:00