Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 12, 2018, 04:42 AM
  • 17 0005_17 0004 _11092018_214239.mp4

Date
09/11/2018
W/O
724194
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00668
PipeID
P13730
Time
9:42 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6001
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
07
Purpose
Routine Assessment
Project
WO_724194_TV17004_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
17 0005
Downstream MH
17 0004
Dir. of Survey
Downstream
Length Surveyed
439.1 ft.
Total Length
439.1 ft.
Structural Index
3
Structural Quick
4J3E
Structural Rating
474
O&M Index
1
O&M Quick
4132
O&M Rating
87
Overall Index
2
Overall Quick
Overall Rating
561
Pipe schematic from manhole 17 0005 to 17 0004
MH: 17 0005MH: 17 0004downstream0 ft. AMH - Upstream Manhole, Survey Begins - 17 00050 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area4.9 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES7.6 ft. FM - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES11.6 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES26.5 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start27 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start27 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES62.5 ft. RFJ - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES, Start65.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"72.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"102.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"122 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"156.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"166.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish166.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start167 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"209.1 ft. RMC - Roots Medium Connection, from 02 to 04 o'clock, 15 %, within 8 inches of joint: NO209.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"209.1 ft. RBL - Roots Ball Lateral, at 02 o'clock, 90 %279.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"294.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"294.9 ft. RML - Roots Medium Lateral, at 10 o'clock, 40 %, within 8 inches of joint: NO369.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"427 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"439 ft. RFJ - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish439 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish439.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish439.1 ft. AMH - Downstream Manhole, Survey Ends - 17 0004

Observation photos (9)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES

    4.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    7.6 ft. - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

    11.6 ft. - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    26.5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    27 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

    27 ft. - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    62.5 ft. - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    166.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Connection, from 02 to 04 o'clock, 15 %, within 8 inches of joint: NO

    209.1 ft. - Roots Medium Connection, from 02 to 04 o'clock, 15 %, within 8 inches of joint: NO

Observations (30)

DistanceCodeObservation
294.9TF
279.8TF
27CM
439RFJ
209.1RMC
439SSS
7.6FM
102.7TF
294.9RML
209.1TF
166.1CM
439.1FM
369.9TF
439.1AMH17 0004
0AMH17 0005
209.1RBL
27RFJ
72.6TF
11.6RFJ
427TF
4.9SSS
167TF
65.1TF
0MWL
26.5SSS
122TF
156.3TF
0MWM
62.5RFJ
166.1FM

Properties (4)

additional_info
SC364816
custom_field_two
2
customer
LACSD
datetime
2018-09-11T21:42:04-07:00