Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 14, 2017, 07:19 AM
Date
04/14/2017
W/O
630215
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00598
PipeID
P12270
Time
12:19 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4466
Sewer Name
15 BALDWIN PARK TRUNK
City
BALDWIN PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_630215_TV15018_APR2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0344
Downstream MH
15 0343
Dir. of Survey
Downstream
Length Surveyed
239.8 ft.
Total Length
239.8 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
141
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
141
Pipe schematic from manhole 15 0344 to 15 0343
MH: 15 0344MH: 15 0343downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 03440 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 30 %of cross sectional area3.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"41.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"45.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"82.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"138.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"143.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"192 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"196 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"239.8 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK239.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish239.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0343

Observations (18)

DistanceCodeObservation
239.8MGOCONNECTION AT MH 9 O'CLOCK
239.8SAV
196TF
0AMH15 0344
0MWL
45.9TF
123.1TFA
138.8TFC
82.1TFC
41.4TF
192TFC
0MGOCONNECTION AT MH 9 O'CLOCK
86.3TFC
9.5TFC
239.8AMH15 0343
143.2TFC
3.1SAV
0MWM

Properties (4)

additional_info
SC345175
custom_field_two
3
customer
LACSD
datetime