Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 18, 2017, 08:46 AM
  • 22 0485_22 0484 _20170418_023943.mp4

Date
04/18/2017
W/O
630167
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00800
PipeID
P16824
Time
1:46 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4355
Sewer Name
22 COVINA CONNECTION EXTENSION TRUNK
City
COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
WO_630167_TV22031_APR2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
22 0485
Downstream MH
22 0484
Dir. of Survey
Downstream
Length Surveyed
177.9 ft.
Total Length
177.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 22 0485 to 22 0484
MH: 22 0485MH: 22 0484downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 04850 ft. MWM - Water Mark, 15 %of cross sectional area3.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start45.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"81.7 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4"133 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"136.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 4"177.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish177.9 ft. MGO - General Observation - CONNECTION AT 3 OC177.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish177.9 ft. AMH - Downstream Manhole, Survey Ends - 22 0484

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
45.5TF
3.7DAGS
133TFC
177.9DAGS
3.7SAV
177.9MGOCONNECTION AT 3 OC
81.7TF
0MWL
0AMH22 0485
136.1TFC
0MWM
177.9SAV
177.9AMH22 0484

Properties (4)

additional_info
SC340719
custom_field_two
3
customer
LACSD
datetime
2017-04-18T01:46:02-07:00