Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 8, 2016, 08:25 AM
  • 02 1313_02 1312_12082016_004801.mp4

Date
12/08/2016
W/O
607634
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00238
PipeID
P03833
Time
12:25 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3935
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_607634_TV02329_DEC2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1313
Downstream MH
02 1312
Dir. of Survey
Downstream
Length Surveyed
320.6 ft.
Total Length
320.6 ft.
Structural Index
3
Structural Quick
3400
Structural Rating
12
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole 02 1313 to 02 1312
MH: 02 1313MH: 02 1312downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13130 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 O CLOCK0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. VC - Vermin Cockroach1.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - WANDERING15.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"22.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"68.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish68.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"71.8 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"73.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"104.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"107.2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"117.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"164.8 ft. CM - Crack Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES165.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"169 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"171.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"175.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"188.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"195.4 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"212.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"280.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"298.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"299 ft. CM - Crack Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES307.8 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"313.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES315.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"319.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish320.6 ft. AMH - Downstream Manhole, Survey Ends - 02 1312

Observation photos (5)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    1.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - WANDERING

    9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - WANDERING

  • Crack Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

    164.8 ft. - Crack Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

    299 ft. - Crack Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    313.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (32)

DistanceCodeObservation
313.4CM
0AMH02 1313
175.9TBA
117.5TFA
0MWL
0MGOLATERAL AT MH 3 O CLOCK
171.9TFC
71.8TBA
0MWM
212.6TFA
298.6TFA
0VC
1.8DAGS
104.5TFC
307.8TBA
299CM
188.8TFC
164.8CM
68.7CM
9CMWANDERING
165.6TFC
319.1DAGS
15.9TFC
195.4TBA
68.7TFC
73.7TFC
280.5TF
315.1TFC
169TBA
107.2TBA
320.6AMH02 1312
22.1TBA

Properties (4)

additional_info
SC317679
custom_field_two
3
customer
LACSD
datetime
2016-12-08T00:25:00-08:00