- Date
- 12/08/2016
- W/O
- 607634
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00238
- PipeID
- P03806
- Time
- 11:12 PM
- Certificate
- U-507-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3936
- Sewer Name
- 02 BELVEDERE TRUNK
- City
- EAST LOS ANGELES, CA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- WO_607634_TV02329_DEC2016
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 02 1289
- Downstream MH
- 02 1288
- Dir. of Survey
- Downstream
- Length Surveyed
- 309.2 ft.
- Total Length
- 309.2 ft.
- Structural Index
- 3
- Structural Quick
- 3200
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 02 1289 to 02 1288 Observation photos (3)

3.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

3.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

304.5 ft. - Crack Multiple, from 01 to 02 o'clock, within 8 inches of joint: NO