Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 5, 2016, 11:07 AM
  • 01 0522_01 0521_12052016_033316.mp4

Date
12/05/2016
W/O
602233
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00206
PipeID
P01007
Time
3:07 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3896
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_602233_TV01017_DEC2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0521
Downstream MH
01 0522
Dir. of Survey
Upstream
Length Surveyed
383.6 ft.
Total Length
383.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
413E
O&M Rating
106
Overall Index
3
Overall Quick
Overall Rating
106
Pipe schematic from manhole 01 0521 to 01 0522
MH: 01 0521MH: 01 0522upstream0 ft. VC - Vermin Cockroach, within 8 inches of joint: NO - AT MH0 ft. AMH - Upstream Manhole, Survey Ends - 01 05220 ft. MGO - General Observation - PIECE OF WOOD AT MH0 ft. OBZ - Obstacles Other, 30 %of cross sectional area, from 03 to 09 o'clock - AT MH0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE1.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish29.9 ft. VC - Vermin Cockroach65.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"68.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"122.8 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 04 to 08 o'clock - DEBRIS138.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"143.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"183 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Finish - DEBRIS217.5 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"246.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"248.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"293.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"319.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"325.6 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 04 to 08 o'clock, Finish - DEBRIS325.6 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS344.9 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS NOT VISIBLE365.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"381.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start383.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE383.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED383.6 ft. MWM - Water Mark, 15 %of cross sectional area383.6 ft. AMH - Downstream Manhole, Survey Begins - 01 0521383.6 ft. VC - Vermin Cockroach, within 8 inches of joint: NO - AT MH383.6 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS

    58 ft. - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS

  • General Observation - PIECE OF WOOD AT MH

    383.6 ft. - General Observation - PIECE OF WOOD AT MH

  • Obstacles Other, 30 %of cross sectional area, from 03 to 09 o'clock - AT MH

    383.6 ft. - Obstacles Other, 30 %of cross sectional area, from 03 to 09 o'clock - AT MH

Observations (29)

DistanceCodeObservation
0MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
64.2TFC
353.7VC
245.4TF
0MGOCONNECTION AT MH 9 O'CLOCK CAPPED
18.1TB
2.1DAGS
383.6VCAT MH
200.6OBZDEBRIS
137.2TFC
134.8TFC
383.6AMH01 0522
240TF
314.8TFC
317.8TFC
0MWM
383.6MGOPIECE OF WOOD AT MH
166.1TBA
382.5DAGS
383.6OBZAT MH
0AMH01 0521
383.6MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
0VCAT MH
260.8OBZDEBRIS
0MWL
90.1TFC
58OBZDEBRIS
58OBZDEBRIS
38.7OBZDEBRIS NOT VISIBLE

Properties (4)

additional_info
SC305230
custom_field_two
4
customer
LACSD
datetime
2016-12-05T03:07:29-08:00