Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 7, 2018, 06:23 AM
  • 16 0046_16 0045 _09062018_232337.mp4

Date
09/06/2018
W/O
723896
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00639
PipeID
P13059
Time
11:23 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6024
Sewer Name
16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
01
Purpose
Routine Assessment
Project
WO_723896_TV16113_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0046
Downstream MH
16 0045
Dir. of Survey
Downstream
Length Surveyed
465.9 ft.
Total Length
465.9 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
276
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
276
Pipe schematic from manhole 16 0046 to 16 0045
MH: 16 0046MH: 16 0045downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 00460 ft. MWL - Water Level, 15 %of cross sectional area5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start462.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish464.1 ft. MGO - General Observation - DAMAGED INVERT AT MH465.9 ft. AMH - Downstream Manhole, Survey Ends - 16 0045

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - DAMAGED INVERT AT MH

    464.1 ft. - General Observation - DAMAGED INVERT AT MH

Observations (7)

DistanceCodeObservation
464.1MGODAMAGED INVERT AT MH
465.9AMH16 0045
5CM
0MWM
0AMH16 0046
0MWL
462.9CM

Properties (4)

additional_info
SC364788
custom_field_two
3
customer
LACSD
datetime
2018-09-06T23:23:22-07:00