- Date
- 04/18/2018
- W/O
- 0695641
- Weather
- Dry
- Operator/Surveyor
- IGNACIO
- Sewer ID
- Z00929
- PipeID
- P22828
- Time
- 8:06 AM
- Certificate
- PENDING
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0827
- Sewer Name
- C JOINT OUTFALL C - UNIT 3E REPLACEMENT
- City
- LONG BEACH
- Loc. details
- Alley
- Location Code
- H
- Use of Sewer
- Sanitary Sewer
- District
- District 03
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- 20180418MI_JOINT_OUTFALL_C_UNIT_3E_REPLACEMENT
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 31.5 in.
- Upstream MH
- C 0591
- Downstream MH
- C 0592
- Dir. of Survey
- Upstream
- Length Surveyed
- 2 ft.
- Total Length
- 2 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 4
- O&M Quick
- 4200
- O&M Rating
- 8
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole C 0591 to C 0592 Observation photos (4)

0 ft. - General Observation - AIRLINE AT MH AT 12 OCLOCK

2 ft. - General Observation - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

2 ft. - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

2 ft. - General Photograph - D/S SIPHON