- Date
- 07/25/2016
- W/O
- 582912
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00274
- PipeID
- P21173
- Time
- 3:44 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3621
- Sewer Name
- 02 INDIANA STREET P.P. CONNECTIONS
- City
- LOS ANGELES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 07A
- Purpose
- Routine Assessment
- Project
- WO_582912_TV02067_JULY2016
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 02 1788
- Downstream MH
- 02 2411
- Dir. of Survey
- Downstream
- Length Surveyed
- 452.6 ft.
- Total Length
- 452.6 ft.
- Structural Index
- 3
- Structural Quick
- 3N00
- Structural Rating
- 219
- O&M Index
- 2
- O&M Quick
- 2Q00
- O&M Rating
- 180
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 399
Pipe schematic from manhole 02 1788 to 02 2411 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

44.1 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

88 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

99.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start