Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 8, 2016, 11:59 AM
  • 02 0381_02 0380A _20160808_060624.mp4

Date
08/08/2016
W/O
252431
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00250
PipeID
P02699
Time
4:59 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3677
Sewer Name
02 DOWNEY AVENUE EXTENSION TRUNK
City
BELLFLOWER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
WO_252431_TV02049_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0381
Downstream MH
02 0380A
Dir. of Survey
Downstream
Length Surveyed
133.7 ft.
Total Length
133.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 0381 to 02 0380A
MH: 02 0381MH: 02 0380Adownstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 02 03810 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE4.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start14.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"103.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"111.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"130.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish133.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0380A133.7 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE

Observation photos (2)

  • General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE

    0.1 ft. - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    103.6 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"

Observations (12)

DistanceCodeObservation
130.4DAGS
111.1TF
0MGOCONNECTION AT THE MH 3 O'CLOCK ACTIVE
133.7AMH02 0380A
0AMH02 0381
103.6TF
0.1MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
133.7MGOCONNECTION AT THE MH 3 O'CLOCK ACTIVE
4.1DAGS
0MWM
0MWL
14.8TFC

Properties (4)

additional_info
SC306007
custom_field_two
4
customer
LACSD
datetime
2016-08-08T04:59:00-07:00