Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 29, 2015, 10:14 AM
  • 02 1324_02 2039_29102015_031525.mp4

Date
10/29/2015
W/O
521098
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00238
PipeID
P03847
Time
3:14 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2818
Sewer Name
02 BELVEDERE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_521098_TV02329_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1324
Downstream MH
02 2039
Dir. of Survey
Downstream
Length Surveyed
200.6 ft.
Total Length
200.6 ft.
Structural Index
4
Structural Quick
4C33
Structural Rating
85
O&M Index
2
O&M Quick
2M00
O&M Rating
140
Overall Index
2
Overall Quick
Overall Rating
225
Pipe schematic from manhole 02 1324 to 02 2039
MH: 02 1324MH: 02 2039downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13240 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start4.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start4.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"19 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"21.6 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start35.7 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish35.8 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start53.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"101.1 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish101.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish165.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"180.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"188.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"200.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish200.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE200.6 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK200.6 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 8 O'CLOCK200.6 ft. AMH - Downstream Manhole, Survey Ends - 02 2039

Observation photos (2)

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    21.6 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    35.8 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

Observations (23)

DistanceCodeObservation
165.5TFA
200.6DAGS
200.6MGOCOCKROACHES IN MANHOLE
180.7TF
53.1TFA
0MWM
200.6MGOCONNECTION AT MH 12 O'CLOCK
0MWL
101.1FM
35.7CM
188.7TFA
21.6CM
0AMH02 1324
101.1DAE
200.6MGOACTIVE CONNECTION AT MH 8 O'CLOCK
35.8FM
93.6TFA
4.7DAE
0MGOCOCKROACHES IN MANHOLE
200.6AMH02 2039
19TFC
4.7TF
2DAGS

Properties (4)

additional_info
SC204150
custom_field_two
3
customer
LACSD
datetime
2015-10-29T03:14:44-07:00