22 0845_22 0844A_10102018_012954.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE
10.2 ft. - General Observation - 30% MAG COAT START 8:00 TO 4:00
30.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG VERY SPORATIC
52 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - CAPPED
61.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
80.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
92.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC
315.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - MULTIPLE LAYER PEELING CONCRETE
354.7 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG
379.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - MULTIPLE LAYER PEELING CONCRETE
| Distance | Code | Observation |
|---|---|---|
| 396.4 | SSS | PEELING CONCRETE |
| 396.7 | AMH | 1:55AM |
| 80.1 | SSS | PEELING CONCRETE |
| 0 | MWL | — |
| 396.4 | MGO | MAG COAT 30% FINISH |
| 0 | AMH | 1:25AM |
| 61.7 | SSS | PEELING CONCRETE |
| 2 | SSS | PEELING CONCRETE |
| 10.2 | MGO | 30% MAG COAT START 8:00 TO 4:00 |
| 297.5 | TFC | Capped |
| 1 | RMB | INSIDE MH |
| 379.6 | SSS | MULTIPLE LAYER PEELING CONCRETE |
| 92.2 | SAV | SEVERE AGG VERY SPORATIC |
| 52 | TFC | CAPPED |
| 0 | MWM | — |
| 354.7 | SAV | SEVERE AGG |
| 315.7 | SSS | MULTIPLE LAYER PEELING CONCRETE |
| 396.4 | SAV | SEVERE AGG SPORATIC |
| 396.4 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 30.7 | SAV | SEVERE AGG VERY SPORATIC |