02 1655_02 1654_1092018_050513.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED
2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
16.7 ft. - Surface Aggregate Missing, from 08 to 11 o'clock, within 8 inches of joint: YES - SEVERE AGG
33.8 ft. - General Observation - 15" NRCP
48.1 ft. - General Observation - DEEP CORRISON 12:00
95.8 ft. - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED
128.1 ft. - Surface Aggregate Missing, from 11 to 01 o'clock, within 8 inches of joint: YES - DEEP CORRISIN 12:00
135.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED
| Distance | Code | Observation |
|---|---|---|
| 2 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 164.1 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 94.6 | TF | Open |
| 128.1 | SAM | DEEP CORRISIN 12:00 |
| 0 | MWL | — |
| 0.8 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 33.8 | MGO | 15" NRCP |
| 2 | SAM | SEVERE AGG |
| 0 | AMH | 5:05AM |
| 164.7 | AMH | 5:25AM |
| 164.1 | SAM | SEVERE AGG |
| 135.7 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 48.1 | MGO | DEEP CORRISON 12:00 |
| 0 | MWM | — |
| 16.7 | SAM | SEVERE AGG |
| 95.8 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |