- Date
- 10/08/2018
- W/O
- #
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00344
- PipeID
- P10402
- Time
- 11:31 PM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0999
- Sewer Name
- G JOINT OUTFALL G - UNIT 4
- City
- COMPTON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 03
- Purpose
- Capital Improvement Program Assesment
- Project
- 20181008MDM_JOINT_OUTFALL_G_UNIT_4
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- G 0040
- Downstream MH
- G 0039
- Dir. of Survey
- Downstream
- Length Surveyed
- 248.9 ft.
- Total Length
- 248.9 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 2
Pipe schematic from manhole G 0040 to G 0039 Observation photos (6)

0 ft. - Water Level, 5 %of cross sectional area - NO FLOW STOPLOG IN PLACE UPSTREAM

71.9 ft. - Material Change, Clay tile (not vitrified clay) - 1 TILE ROW

71.9 ft. - Surface Other, from 11 to 01 o'clock, within 8 inches of joint: YES - 2 PARTIAL MISSING TILES

98.2 ft. - General Photograph - CONCRETE PATCH

98.2 ft. - Repair Patch, from 09 to 12 o'clock, within 8 inches of joint: YES - CONCRETE PATCH

225.9 ft. - General Observation - 33" VCP