- Date
- 04/13/2018
- W/O
- 0700687
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00722
- PipeID
- P15322
- Time
- 11:27 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7682
- Sewer Name
- 19 EAST ARTESIA TRUNK, SECTS 1,2,3,&5
- City
- CERRITOS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 05
- Purpose
- Routine Assessment
- Project
- 20180413DF_EAST_ARTESIA_TR_SECS_1_2_3_5
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 19 0132
- Downstream MH
- 19 0133
- Dir. of Survey
- Upstream
- Length Surveyed
- 238 ft.
- Total Length
- 238 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 19 0132 to 19 0133 Observation photos (8)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

29.9 ft. - General Photograph

75 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, at 09 o'clock, , within 8 inches of joint: YES

75 ft. - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4" - Open

97.7 ft. - General Photograph

161.1 ft. - General Photograph

163.5 ft. - General Photograph