Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 11, 2016, 07:53 AM
  • 30 0225_30 0224 _08112016_005320.mp4

Date
08/11/2016
W/O
579962
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00884
PipeID
P17924
Time
12:53 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3632
Sewer Name
30 VIA CAMPESINA TRUNK
City
PALOS VERDES ESTATES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
09
Purpose
Routine Assessment
Project
WO_579962_TV30062_JULY2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
30 0225
Downstream MH
30 0224
Dir. of Survey
Downstream
Length Surveyed
257.9 ft.
Total Length
257.9 ft.
Structural Index
4
Structural Quick
4G00
Structural Rating
160
O&M Index
2
O&M Quick
312H
O&M Rating
97
Overall Index
3
Overall Quick
Overall Rating
257
Pipe schematic from manhole 30 0225 to 30 0224
MH: 30 0225MH: 30 0224downstream0 ft. AMH - Upstream Manhole, Survey Begins - 30 02250 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area4 ft. FM - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES24.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start38.1 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES68.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start77.7 ft. TBD - Tap Break-In Defective, at 09 o'clock, -, , within 8 inches of joint: YES, 6" - DEBRIS169.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"257.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish257.9 ft. AMH - Downstream Manhole, Survey Ends - 30 0224257.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

    4 ft. - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    24.9 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    38.1 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    68.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Defective, at 09 o'clock, -,  , within 8 inches of joint: YES, 6" - DEBRIS

    77.7 ft. - Tap Break-In Defective, at 09 o'clock, -, , within 8 inches of joint: YES, 6" - DEBRIS

Observations (12)

DistanceCodeObservation
0AMH30 0225
257.9DSZ
38.1FM
0MWM
68.9FM
77.7TBDDEBRIS
4FM
0MWL
169.2TF
24.9DSZ
257.9AMH30 0224
257.9FM

Properties (4)

additional_info
SC306066
custom_field_two
3
customer
LACSD
datetime
2016-08-11T00:53:03-07:00