Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 24, 2016, 06:41 AM
  • 18 090018 0899District 18_052316_234224SO_MPEGPosition.mp4

Date
05/23/2016
W/O
574709
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00709
PipeID
P14751
Time
11:41 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3387
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_574709_TV18101_JUNE2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
18 0900
Downstream MH
18 0899
Dir. of Survey
Downstream
Length Surveyed
9.5 ft.
Total Length
9.5 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 0900 to 18 0899
MH: 18 0900MH: 18 0899downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 09002.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start9.5 ft. MSA - Survey Abandoned - VIEW OF DOWN LEG OF THE U/S SIPHON9.5 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish

Observation photos (2)

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Survey Abandoned - VIEW OF DOWN LEG OF THE U/S SIPHON

    9.5 ft. - Survey Abandoned - VIEW OF DOWN LEG OF THE U/S SIPHON

Observations (6)

DistanceCodeObservation
0MWL
9.5MSAVIEW OF DOWN LEG OF THE U/S SIPHON
0MWM
0AMH18 0900
9.5SRV
2.1SRV

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2016-05-23T23:41:57-07:00