Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 29, 2016, 09:57 AM
  • 18 0741_18 0740_20160429_030814.mpg

Date
04/29/2016
W/O
568699
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14594
Time
2:57 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3357
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
RFIR_WO_568699_TV18103_MAY2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Upstream MH
18 0741
Downstream MH
18 0740
Dir. of Survey
Downstream
Length Surveyed
424.9 ft.
Total Length
424.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0741 to 18 0740
MH: 18 0741MH: 18 0740downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 07410 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area3.1 ft. MGO - General Observation - MAG COAT 25%278.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"424.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0740

Observations (6)

DistanceCodeObservation
0AMH18 0741
0MWM
0MWL
278.4TF
3.1MGOMAG COAT 25%
424.9AMH18 0740

Properties (4)

additional_info
SC300353
custom_field_two
3
customer
LACSD
datetime
2016-04-29T02:57:09-07:00