Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 20, 2018, 09:03 AM
  • 19 0207_19 0206_20092018_020851.mp4

Date
09/20/2018
W/O
724117
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00726
PipeID
P15176
Time
2:03 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6111
Sewer Name
19 NORWALK BOULEVARD TRUNK
City
CERRITOS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_724117_TV19068_SEPT2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
19 0207
Downstream MH
19 0206
Dir. of Survey
Downstream
Length Surveyed
240.7 ft.
Total Length
240.7 ft.
Structural Index
3
Structural Quick
413H
Structural Rating
139
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
139
Pipe schematic from manhole 19 0207 to 19 0206
MH: 19 0207MH: 19 0206downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 02072.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start23.3 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES174.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"226.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"228.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish230.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"240.7 ft. AMH - Downstream Manhole, Survey Ends - 19 0206

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    23.3 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    226.1 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (10)

DistanceCodeObservation
23.3FM
0MWL
2.4CM
174.4TFC
0MWM
228.2CM
0AMH19 0207
226.1TB
240.7AMH19 0206
230.7TFC

Properties (4)

additional_info
SC364827
custom_field_two
3
customer
LACSD
datetime
2018-09-20T02:03:50-07:00