Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2017, 08:02 AM
  • 18 0259_18 0258 _10072017_010323.mp4

Date
07/10/2017
W/O
640666
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00672
PipeID
P14087
Time
1:02 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4639
Sewer Name
18 BROADWAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
13
Purpose
Routine Assessment
Project
WO_640666_TV18003_JUN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0259
Downstream MH
18 0258
Dir. of Survey
Downstream
Length Surveyed
71.9 ft.
Total Length
71.9 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 18 0259 to 18 0258
MH: 18 0259MH: 18 0258downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 02590 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE0 ft. MGO - General Observation - CONNECTION AT MH 3 ACTIVE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area35.5 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES43 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES44.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"59.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES71.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0258

Observation photos (3)

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    35.5 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    43 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    59.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
0AMH18 0259
44.7TFC
0MGOCONNECTION AT MH 9 ACTIVE
43CL
0MGOCONNECTION AT MH 3 ACTIVE
59.1CM
35.5CL
0MWL
71.9AMH18 0258
0MWM

Properties (4)

additional_info
SC345385
custom_field_two
3
customer
LACSD
datetime
2017-07-10T01:02:39-07:00