18 1087_18 1085 _20170522_015738.mp4
7.1 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES
13.6 ft. - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES
19.6 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES
37.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
93 ft. - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES
179.3 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
237.5 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start
258.9 ft. - Crack Multiple, from 10 to 05 o'clock, within 8 inches of joint: YES
265.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
283.7 ft. - Obstacles In Joint, 5 %of cross sectional area, at 12 o'clock - GASKET
283.7 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
326.5 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES
332.6 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES
351.1 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES
379.7 ft. - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: NO
387.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 13.6 | CS | — |
| 258.9 | CM | — |
| 0 | MGO | HEAVY STEAM IN PIPE |
| 93 | FS | — |
| 351.1 | FL | — |
| 179.3 | CL | — |
| 7.1 | CL | — |
| 332.6 | FL | — |
| 237.5 | DAE | — |
| 0 | AMH | 18 1085 |
| 37.3 | CM | — |
| 283.7 | OBJ | GASKET |
| 19.6 | FS | — |
| 265.1 | CL | — |
| 387.7 | CL | — |
| 326.5 | FL | — |
| 400.8 | DAE | — |
| 379.7 | CC | — |
| 283.7 | CL | — |
| 0 | MWM | — |
| 0 | MWL | — |
| 400.8 | AMH | 18 1087 |