- Date
- 12/29/2017
- W/O
- 679275
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00016
- PipeID
- P00031
- Time
- 12:43 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5298
- Sewer Name
- 08 MAIN STREET TRUNK
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_679275_TV08116_JAN2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 08 0028
- Downstream MH
- 08 0029
- Dir. of Survey
- Upstream
- Length Surveyed
- 422.1 ft.
- Total Length
- 422.2 ft.
- Structural Index
- 3
- Structural Quick
- 3P00
- Structural Rating
- 252
- O&M Index
- 2
- O&M Quick
- 2P00
- O&M Rating
- 168
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 420
Pipe schematic from manhole 08 0028 to 08 0029 Observation photos (2)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.1 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start