Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2017, 10:45 AM
  • 08 0048_08 0047 _28122017_025702.mp4

Date
12/28/2017
W/O
679275
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00050
Time
2:45 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5297
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_679275_TV08116_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
08 0047
Downstream MH
08 0048
Dir. of Survey
Upstream
Length Surveyed
277.8 ft.
Total Length
277.8 ft.
Structural Index
3
Structural Quick
3I21
Structural Rating
146
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
146
Pipe schematic from manhole 08 0047 to 08 0048
MH: 08 0047MH: 08 0048upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 08 00480 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK2.8 ft. MGO - General Observation - SPALLING THROUGHOUT THE REACH, FROM 08 TO 04 O'CLOCK4.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish28.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"79.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"131.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"230.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.8 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES272.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"275.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start277.8 ft. AMH - Downstream Manhole, Survey Begins - 08 0047277.8 ft. MWM - Water Mark, 10 %of cross sectional area277.8 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    22 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
198.1TFC
0AMH08 0047
146.4TF
249.1TFC
277.8MGOCONNECTION AT MH 9 O'CLOCK
2CM
0MWM
103.1TFC
277.8AMH08 0048
5.3TFC
22CL
277.8MGOCONNECTION AT MH 3 O'CLOCK
273.4CM
275MGOSPALLING THROUGHOUT THE REACH, FROM 08 TO 04 O'CLOCK
47.4TFC
0MWL

Properties (4)

additional_info
SC346771
custom_field_two
3
customer
LACSD
datetime
2017-12-28T02:45:20-08:00