Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2017, 11:41 AM
  • 08 0046_08 0045 _28122017_035453.mp4

Date
12/28/2017
W/O
679275
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00048
Time
3:41 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5297
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_679275_TV08116_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
08 0046
Downstream MH
08 0045
Dir. of Survey
Downstream
Length Surveyed
315.5 ft.
Total Length
315.5 ft.
Structural Index
3
Structural Quick
3421
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 08 0046 to 08 0045
MH: 08 0046MH: 08 0045downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 00460 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES5 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES39.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"46 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start89.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"142.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"193.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"239.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish241.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"255.5 ft. CM - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES293.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"313 ft. MGO - General Observation - 5% GREASE THROUGHOUT THE REACH, FROM 08 TO 04 O'CLOCK314 ft. MGO - General Observation - SPALLING THROUGHOUT THE REACH, FROM 08 TO 04 O'CLOCK315.5 ft. AMH - Downstream Manhole, Survey Ends - 08 0045

Observation photos (4)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    5 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    46 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    255.5 ft. - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
142.7TFC
0AMH08 0046
293.2TFC
89.9TFC
2CM
314MGOSPALLING THROUGHOUT THE REACH, FROM 08 TO 04 O'CLOCK
5CL
0MWM
313MGO5% GREASE THROUGHOUT THE REACH, FROM 08 TO 04 O'CLOCK
315.5AMH08 0045
39.4TFC
255.5CM
239.2CM
193.7TF
46CM
241.1TFC
0MWL

Properties (4)

additional_info
SC346771
custom_field_two
3
customer
LACSD
datetime
2017-12-28T03:41:53-08:00