Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 24, 2018, 07:31 AM
  • 16 0358_16 0357_9242018_013321.mp4

Date
09/24/2018
W/O
0729304
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00665
PipeID
P13409
Time
12:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0978
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Capital Improvement Program Assesment
Project
20180921MDM_SAN_MARINO_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
14 in.
Upstream MH
16 0358
Downstream MH
16 0357
Dir. of Survey
Downstream
Length Surveyed
181.8 ft.
Total Length
181.8 ft.
Structural Index
2
Structural Quick
4134
Structural Rating
38
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
38
Pipe schematic from manhole 16 0358 to 16 0357
MH: 16 0358MH: 16 0357downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:20AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area4.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE4.3 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H6.9 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT10.1 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - H11.9 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H14.3 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H17.2 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H17.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SL19.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL22.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL24.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H25.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Active27.3 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL29.8 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS29.8 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS29.8 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS29.8 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS138.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open181.2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 40% HAIRLINE AT JOINTS181.2 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 15% SLIGHT AT JOINTS181.2 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 20% HAIRLINE AT JOINTS181.2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 70%SLIGHT AT JOINTS181.8 ft. AMH - Downstream Manhole, Survey Ends - 1:50AM

Observations (26)

DistanceCodeObservation
0AMH1:20AM
29.8FLHAIRLINE AT JOINTS
4.3FCHAIRLINE
22.1FMSL
0MWL
0MWM
6.9FCSLIGHT
10.1FCH
17.2FCH
14.3FCH
27.3FCSL
181.2FC40% HAIRLINE AT JOINTS
17.2FLSL
29.8FCHAIRLINE AT JOINTS
138.6TFOpen
25.9TFActive
181.8AMH1:50AM
24.5FLH
29.8FLSLIGHT AT JOINTS
4.3FCH
181.2FL15% SLIGHT AT JOINTS
11.9FCH
181.2FL20% HAIRLINE AT JOINTS
181.2FC70%SLIGHT AT JOINTS
29.8FCSLIGHT AT JOINTS
19.5FCSL

Properties (4)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2018-09-24T00:31:14-07:00