H 0401A_H 0401_9212018_130801.mp4
2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 60% MAG
2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
42.7 ft. - General Photograph
123.3 ft. - General Photograph
124.4 ft. - General Photograph
225.2 ft. - General Photograph
225.3 ft. - General Photograph
328.9 ft. - General Photograph
| Distance | Code | Observation |
|---|---|---|
| 2 | SRC | — |
| 458 | SSS | — |
| 0 | AMH | 1:05 PM |
| 462.5 | AMH | 1:24 PM |
| 225.2 | MGP | — |
| 123.3 | MGP | — |
| 0 | MWM | — |
| 2 | SAV | — |
| 462.5 | MGO | Peeling & Flaking Throughout The Reach |
| 462.5 | MGO | GREASE THROUGHOUT THE REACH (5%) |
| 2 | SSS | — |
| 225.3 | MGP | — |
| 328.9 | MGP | — |
| 2 | SZ | 60% MAG |
| 0 | MWL | — |
| 457.9 | SAV | — |
| 2 | SAP | — |
| 42.7 | MGP | — |
| 458 | SRV | — |
| 458 | SZ | 65% MAG |
| 458 | SRC | — |
| 2 | SRV | — |
| 124.4 | MGP | — |
| 458 | SAP | — |