Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 12, 2017, 06:47 AM
Date
10/11/2017
W/O
663065
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00601
PipeID
P12544
Time
11:47 PM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4828
Sewer Name
15 DOUBLE AVENUE TRUNK
City
TEMPLE CITY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_663065_TV15183_OCT2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0610
Downstream MH
15 0609A
Dir. of Survey
Downstream
Length Surveyed
225.5 ft.
Total Length
225.5 ft.
Structural Index
3
Structural Quick
4536
Structural Rating
44
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
44
Pipe schematic from manhole 15 0610 to 15 0609A
MH: 15 0610MH: 15 0609Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 06100 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area15.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES33.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES54.2 ft. FM - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES64.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"66.2 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES91.7 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"93 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES104.9 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES113.8 ft. CM - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES122.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES134.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES140.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES148.4 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"158.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES167.6 ft. CM - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES181.4 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"188.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES209.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES225.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK225.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0609A

Observation photos (14)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    15.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    33.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

    54.2 ft. - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    66.2 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    93 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    104.9 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

    113.8 ft. - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    122.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    134.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    140.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    158.7 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

    167.6 ft. - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    188.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    209.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
91.7TFC
0AMH15 0610
140.9CL
181.4TFC
54.2FM
33.6CL
104.9FL
0MWM
188.5CM
66.2CL
167.6CM
122.8CM
209.3FM
134.5FM
0MWL
15.9FM
225.5MGOCONNECTION AT MH 9 O'CLOCK
93FM
113.8CM
158.7CM
225.5AMH15 0609A
148.4TFA
64.7TF

Properties (4)

additional_info
SC353079
custom_field_two
3
customer
LACSD
datetime