Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 31, 2017, 10:52 PM
  • H 0403A_A 0575_291117_121941.mp4

Date
10/31/2017
W/O
630138
Weather
Dry
Operator/Surveyor
E RUIZ
Sewer ID
Z00177
PipeID
P10834
Time
3:52 PM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5140
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
WO_630138_TV18073_NOV2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Width
60 in.
Upstream MH
H 0403A
Downstream MH
A 0575
Dir. of Survey
Downstream
Length Surveyed
8 ft.
Total Length
8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole H 0403A to A 0575
MH: H 0403AMH: A 0575downstream0 ft. MWL - Water Level, 45 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 0403A1.1 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. MGO - General Observation - REINFORCEMENT CORRODED/BROKEN AT THE START OF THE PIPE7.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE8 ft. AMH - Downstream Manhole, Survey Ends - A 0575

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    1.1 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
1.1SAP
2MGOREINFORCEMENT CORRODED/BROKEN AT THE START OF THE PIPE
7.1MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
0MWL
0MWM
8AMHA 0575
0AMHH 0403A

Properties (4)

additional_info
SC348350
custom_field_two
1
customer
LACSD
datetime
2017-10-31T15:52:10-07:00