Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 11, 2016, 07:20 AM
  • 15 0221_15 0220_11052016_002040.mp4

Date
05/11/2016
W/O
568733
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00627
PipeID
P12143
Time
12:20 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3346
Sewer Name
15 SAN JOSE CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
33
Purpose
Routine Assessment
Project
WO_568733_TV15133_MAY2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
15 0221
Downstream MH
15 0220
Dir. of Survey
Downstream
Length Surveyed
154.9 ft.
Total Length
154.9 ft.
Structural Index
3
Structural Quick
3E2E
Structural Rating
150
O&M Index
2
O&M Quick
2F00
O&M Rating
72
Overall Index
2
Overall Quick
Overall Rating
222
Pipe schematic from manhole 15 0221 to 15 0220
MH: 15 0221MH: 15 0220downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 02210 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start125.3 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start152.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish152.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish152.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish152.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE152.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish154.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK154.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0220

Observations (15)

DistanceCodeObservation
152.9DSZ
152.9SSS
152.9DAGS
2SSS
154.9MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0AMH15 0221
0MWL
152.9MGOCOCKROACHES IN MANHOLE
2DAGS
2SAP
0MWM
0MGOCOCKROACHES IN MANHOLE
125.3DSZ
154.9AMH15 0220
152.9SAP

Properties (4)

additional_info
SC305625
custom_field_two
3
customer
LACSD
datetime
2016-05-11T00:20:24-07:00