Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2017, 05:26 AM
Date
05/03/2017
W/O
630297
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14301
Time
10:26 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4483
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_630297_TV18092_APR2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0450
Downstream MH
18 0449
Dir. of Survey
Downstream
Length Surveyed
314.3 ft.
Total Length
314.3 ft.
Structural Index
3
Structural Quick
3K23
Structural Rating
180
O&M Index
2
O&M Quick
2D00
O&M Rating
50
Overall Index
3
Overall Quick
Overall Rating
230
Pipe schematic from manhole 18 0450 to 18 0449
MH: 18 0450MH: 18 0449downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 04500 ft. MGO - General Observation - HEAVY STEAM2 ft. MMC - Material Change, Vitrified clay pipe5.4 ft. CS - Crack Spiral, from 08 to 02 o'clock, within 8 inches of joint: YES10.2 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES15.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES17.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"25.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start59 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"79.4 ft. TBI - Tap Break-In Intruding, at 03 o'clock, -, -, within 8 inches of joint: YES, 6", 2"85.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"110.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"136.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"162.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"177.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"193 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"194.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start214 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"235 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish235.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start240 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"260.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"286.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"302.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"314.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0449314.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK314.3 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish314.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (7)

  • Crack Spiral, from 08 to 02 o'clock, within 8 inches of joint: YES

    5.4 ft. - Crack Spiral, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    10.2 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    15.5 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    25.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 03 o'clock, -, -, within 8 inches of joint: YES, 6", 2"

    79.4 ft. - Tap Break-In Intruding, at 03 o'clock, -, -, within 8 inches of joint: YES, 6", 2"

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    194.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Settled Other,  10 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    235.1 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (29)

DistanceCodeObservation
177.8TFC
25.5CM
5.4CS
235.1DSZ
85.1TFC
314.3AMH18 0449
110.8TFC
0MGOCONNECTION AT MH 3 O'CLOCK
15.5CL
302.4TFC
194.1DAE
193TF
2MMC
59TFC
17.3TFC
0AMH18 0450
314.3MGOCONNECTION AT MH 3 O'CLOCK
136.5TFC
235DAE
286.7TFC
79.4TBI
214TFC
10.2CL
0MGOHEAVY STEAM
240TFC
260.6TFC
314.3DSZ
314.3CM
162.6TFC

Properties (4)

additional_info
SC345193
custom_field_two
3
customer
LACSD
datetime
2017-05-03T22:26:00-07:00