Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 5, 2017, 08:50 AM
  • Section#1_F 0032_F 0031__852017__G6792.mp4

Date
08/05/2017
W/O
0646716
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00033
PipeID
P11207
Time
1:50 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6792
Sewer Name
F JOINT OUTFALL F - UNIT 1
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20170805MDM_JOINT_OUTFALL_F_UNIT_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
69 in.
Upstream MH
F 0032
Downstream MH
F 0031
Dir. of Survey
Downstream
Length Surveyed
284.5 ft.
Total Length
284.5 ft.
Structural Index
5
Structural Quick
5K4J
Structural Rating
533
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
537
Pipe schematic from manhole F 0032 to F 0031
MH: F 0032MH: F 0031downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - MH CONN OPEN STOPLOG IN PLACE0 ft. AMH - Upstream Manhole, Survey Begins - 1:50AM2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG18.1 ft. MGO - General Observation - 69" RCP18.1 ft. SRV - Surface Reinforcement Visible, from 11 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR24.9 ft. SRV - Surface Reinforcement Visible, from 11 to 03 o'clock, within 8 inches of joint: NO - CIRCUM94.4 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR107.4 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG115.1 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR115.1 ft. SRV - Surface Reinforcement Visible, from 11 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR145.9 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR185.2 ft. SRV - Surface Reinforcement Visible, from 10 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR216.6 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR270 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE273.7 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, Start - LONG REBAR284.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG284.2 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, Finish - LONG REBAR284.2 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR284.5 ft. AMH - Downstream Manhole, Survey Ends - 2:25AM

Observation photos (10)

  • General Observation - 69" RCP

    18.1 ft. - General Observation - 69" RCP

  • Surface Reinforcement Visible, from 11 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    18.1 ft. - Surface Reinforcement Visible, from 11 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Visible, from 11 to 03 o'clock, within 8 inches of joint: NO - CIRCUM

    24.9 ft. - Surface Reinforcement Visible, from 11 to 03 o'clock, within 8 inches of joint: NO - CIRCUM

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    94.4 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    107.4 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    115.1 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

    145.9 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

  • Surface Reinforcement Visible, from 10 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    185.2 ft. - Surface Reinforcement Visible, from 10 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    216.6 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

    273.7 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

Observations (22)

DistanceCodeObservation
284.2SAMSEVERE AGG
24.9SRVCIRCUM
185.2SRVCIRCUM REBAR
0MWL
18.1MGO69" RCP
270TFACTIVE
284.2SRVLONG REBAR
0MWM
2SRCCIRCUM REBAR
18.1SRVCIRCUM REBAR
0MGOMH CONN OPEN STOPLOG IN PLACE
94.4SRCCIRCUM REBAR
284.2SRVCIRCUM REBAR
273.7SRVLONG REBAR
115.1SRVCIRCUM REBAR
216.6SRCCIRCUM REBAR
145.9SRVLONG REBAR
2SAMSEVERE AGG
284.5AMH2:25AM
107.4SAMSEVERE AGG
115.1SRVCIRCUM REBAR
0AMH1:50AM

Properties (4)

custom_field_three
CIRCUM REBAR CORRODED
custom_field_two
2
customer
LACSD
datetime
2017-08-05T01:50:46-07:00