19 0090_19 0089_842017_120714.mp4
3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO
3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
14.2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO
46.6 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO
62.7 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO
78.6 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO
88.4 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO
97.2 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO
102.7 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO
106.9 ft. - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO
113.8 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO
131.7 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO
138.5 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
160.6 ft. - Surface Reinforcement Visible, from 09 to 10 o'clock, within 8 inches of joint: NO
| Distance | Code | Observation |
|---|---|---|
| 102.7 | SRV | — |
| 131.7 | SRV | — |
| 88.4 | SRV | — |
| 138.5 | SRV | — |
| 97.2 | SRV | — |
| 173.3 | AMH | 1230 |
| 3 | SRC | — |
| 62.7 | SRV | — |
| 94.1 | SRV | — |
| 113.8 | SRV | — |
| 46.6 | SRV | — |
| 160.6 | SRV | — |
| 0 | MWL | — |
| 106.9 | SRV | — |
| 170.8 | SAV | — |
| 14.2 | SRV | — |
| 0 | MWM | — |
| 78.6 | SRV | — |
| 0 | AMH | 1205 |
| 3 | SAV | — |
| 148.8 | SRV | — |
| 173.3 | MGO | ACTIVE CONN. @ 3 IN THE MH |