Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2017, 10:41 AM
  • 18 0490_18 0489_12272017_025534.mp4

Date
12/27/2017
W/O
0679385
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00691
PipeID
P14344
Time
2:41 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0708
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
12272017VMR_NORTH_PLANT_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Upstream MH
18 0490
Downstream MH
18 0489
Dir. of Survey
Downstream
Length Surveyed
100 ft.
Total Length
100 ft.
Structural Index
2
Structural Quick
3525
Structural Rating
31
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
31
Pipe schematic from manhole 18 0490 to 18 0489
MH: 18 0490MH: 18 0489downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02:50 AM0 ft. MWL - Water Level, 20 %of cross sectional area8 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES10 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start12.6 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES23 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish23 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES43.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES48.5 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES51.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES52.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start64.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES66.5 ft. CC - Crack Circumferential, from 11 to 03 o'clock, within 8 inches of joint: YES71.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish76.6 ft. CC - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES79.3 ft. CC - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES81.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES87 ft. CC - Crack Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES89.3 ft. CC - Crack Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES96.9 ft. CC - Crack Circumferential, from 11 to 03 o'clock, within 8 inches of joint: YES100 ft. AMH - Downstream Manhole, Survey Ends - 03:36 AM100 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 10"

Observations (23)

DistanceCodeObservation
76.6CC
0MWM
48.5CM
79.3CC
71.6CL
0AMH02:50 AM
100AMH03:36 AM
10CL
64.2CM
23CL
87CC
96.9CC
51.2CM
8CM
12.6CL
81.7CL
89.3CC
52.7CL
66.5CC
23CL
100TFA
0MWL
43.7CM

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2017-12-27T02:41:21-08:00