Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 15, 2017, 08:48 AM
  • J 0492_J 0491_12152017_013950.mp4

Date
12/15/2017
W/O
0624519
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P24757
Time
12:48 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0703
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47
Purpose
Capital Improvement Program Assesment
Project
20171215MDM_JOINT_OUTFALL_J_UNIT_1E
Material
RGRCP
Shape
Circular
Height
30 in.
Upstream MH
J 0492
Downstream MH
J 0491
Dir. of Survey
Downstream
Length Surveyed
506.6 ft.
Total Length
506.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole J 0492 to J 0491
MH: J 0492MH: J 0491downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:40AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area11.1 ft. MGO - General Observation - WHITE BUILD UP ON PIPE12.4 ft. MGO - General Observation - 30" RGRCP205.7 ft. MGO - General Observation - CAMERA PULLED BACK FOR REPAIR316.8 ft. MGO - General Observation - 30" RGRCP461.8 ft. MGO - General Observation - WHITE MATERIAL ON PIPE506.6 ft. AMH - Downstream Manhole, Survey Ends(ABANDONED MH) - 2:55AM

Observation photos (5)

  • General Observation - WHITE BUILD UP ON PIPE

    11.1 ft. - General Observation - WHITE BUILD UP ON PIPE

  • General Observation - 30" RGRCP

    12.4 ft. - General Observation - 30" RGRCP

  • General Observation - 30" RGRCP

    316.8 ft. - General Observation - 30" RGRCP

  • General Observation - WHITE MATERIAL ON PIPE

    461.8 ft. - General Observation - WHITE MATERIAL ON PIPE

  • Downstream Manhole, Survey Ends(ABANDONED MH) - 2:55AM

    506.6 ft. - Downstream Manhole, Survey Ends(ABANDONED MH) - 2:55AM

Observations (9)

DistanceCodeObservation
316.8MGO30" RGRCP
0AMH1:40AM
0MWL
0MWM
11.1MGOWHITE BUILD UP ON PIPE
461.8MGOWHITE MATERIAL ON PIPE
12.4MGO30" RGRCP
205.7MGOCAMERA PULLED BACK FOR REPAIR
506.6AMH2:55AM

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2017-12-15T00:48:21-08:00
year_laid
20020501