Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2017, 12:18 PM
  • 18 0454_18 0036_12292017_044422.mp4

Date
12/28/2017
W/O
0679385
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00691
PipeID
P14306
Time
4:18 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0712
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
12272017VMR_NORTH_PLANT_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
18 0454
Downstream MH
18 0036
Dir. of Survey
Downstream
Length Surveyed
99.6 ft.
Total Length
99.6 ft.
Structural Index
2
Structural Quick
3228
Structural Rating
24
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
24
Pipe schematic from manhole 18 0454 to 18 0036
MH: 18 0454MH: 18 0036downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05:08 AM0 ft. TFA - Tap Factory Made Active, at 04 o'clock, -, within 8 inches of joint: NO, 6"0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area18.8 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES20.7 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES20.7 ft. CC - Crack Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES23.5 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES26 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES31.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES41.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES43.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES49.3 ft. CC - Crack Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES56.2 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES66.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start82.1 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES94.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish99.6 ft. AMH - Downstream Manhole, Survey Ends - 05:34 AM99.6 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 12"

Observations (19)

DistanceCodeObservation
41.2CL
49.3CC
0AMH05:08 AM
99.6AMH05:34 AM
94.1CL
56.2CL
20.7CL
0TFA
82.1CL
20.7CC
23.5CL
31.6CL
66.6CL
99.6TFA
0MWM
0MWL
18.8CM
43.8CM
26CL

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2017-12-28T04:18:00-08:00